Description and application

Shielded extra flexible control cable for motion applications. For its protected installation inside and outside of train and bus (Rolling Stock). Certified to EN 45545-2 Risk level HL1-HL3. Electromagnetic interference (EMI) protection.
  • Markets
  • Location
    Indoors/Outdoors
  • Type of installation
    Flexible and continuous movement

Design

  • Overall cable shield
    Tin plated copper wire braid
  • Conductor
    Polished copper wires, extra flexible Class 6 according to EN 60228 and IEC 60228
  • Insulation
    Sumsave®
  • Identification
    Numbered black + one yellow/green conductor
  • Sheath
    M-Line type polyolefin
  • Colour
    Black

Technical characteristics

  • Service temperature in fixed and protected installation
    -40 °C to +105 °C
  • Service voltage
    300 V/500 V
  • Service temperature in flexible installation
    -30 °C to +105 °C
  • Service temperature in mobile installation
    -20 °C to +105 °C
  • Temperature during handling, transport and storage
    +5 °C to +50 °C
  • Test voltage
    2.500 V
  • Minimum bend radius in fixed installation
    5 x outer diameter
  • Minimum bend radius in flexible installation
    7.5 x outer diameter
  • Minimum bend radius for mobile installation (free movement)
    7.5 x outer diameter
  • Minimum bend radius for installation in cable chain. Movement <10 m (Ambient temperature
    +10 °C to +60 °C)

Other properties

  • Standards of reference
    EN 45545-2
  • Certification
    EN 45545-2 HL1-HL3
  • Water resistance
    AD3 aerosols (possibility of water falling as a spray at an angle of up to 60°)
  • Oil resistance
    IEC 60811-404
  • UV resistance
    Excellent
  • Chemical resistance in general
    Please refer to technical appendix
  • RoHS
    Free of harmful substances according to RoHS II - Directive 2011/65/EU and Delegated Directive (EU) 2015/863 amending Annex II of Directive 2011/65/EU

Fire resistant properties

  • Halogen-free
    EN 60754-1, IEC 60754-1, VDE 0482-754-1
  • Flame retardant
    EN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2, NFC 32070 C2
  • Fire retardant
    EN 60332-3-24, IEC 60332-3-24, VDE 0482-332-3-24

Other colours and configurations possible on request. Sumcab Specialcable Group S.L. (Sumcab) reserves the right to make changes to the product described in this specification without prior notice.While Sumcab makes every reasonable effort to ensure the accuracy of the data at the time of this publication, the information and specifications described in this document are subject to errors or omissions. Sumcab assumes no responsibility that may arise from the use of this specification. Drawings are not to scale unless otherwise specified and are provided for general and informational purposes only. All values represented in this specification should be used only as a guide.