Description and application
Power cable for offshore installations (ships and platforms) with SHF2 type sheath resistant to mud, grease and industrial oils.
-
Markets
-
LocationOutdoors
-
Type of installationFixed
Design
-
ArmouringCopper braid
- ConductorTinned copper, multi-wire Class 2 according to EN 60228 and IEC 60228
- InsulationEPR
- IdentificationWhite with black numbering
- Grip colourBlack
- SheathSHF2 - MUD type polyolefin
- ColourBlack
Technical characteristics
-
Service temperature in fixed and protected installation-40 °C to +90 °C
-
Service voltage0.6/1kV
- Temperature during handling, transport and storage+5 °C to +50 °C
- Max. conductor temperature+90 °C
- Max. temperature in short circuit (max. 5 sec)+250 °C
- Test voltage3.500 V
- Minimum bend radius in fixed installation≤ 25 mm = 4 x outer diameter. > 25 mm = 6 x outer diameter
Other properties
- Standards of referenceNEK 606, IEC 60092-350, IEC 60092-351, IEC 60092-353, IEC 60092-359
- CertificationABS, DNV-GL
- Water resistanceAD7 Partial immersion (possibility of total or partial coverage by water partially and intermittently.)
- Impact resistanceAG2 Medium (industrial use)
- Oil resistanceIEC 60811-404 in conditions according to IEC 60092-360 SHF2
- Resistance to hydrocarbonsIEC 60811-404 in conditions according to IEC 60092-360 SHF2
- UV resistanceIEC 60811-404 in conditions according to IEC 60092-360 SHF2
- Chemical resistance in generalPlease refer to technical appendix
- RoHSFree of harmful substances according to RoHS II - Directive 2011/65/EU and Delegated Directive (EU) 2015/863 amending Annex II of Directive 2011/65/EU
Fire resistant properties
-
Halogen-freeIEC 60754-1
- Flame retardantIEC 60332-1-2
- Fire retardantIEC 60332-3-22
- Low smoke opacityIEC 61034-2
- Low gas corrosivityIEC 60754-2
Other colours and configurations possible on request. Sumcab Specialcable Group S.L. (Sumcab) reserves the right to make changes to the product described in this specification without prior notice.While Sumcab makes every reasonable effort to ensure the accuracy of the data at the time of this publication, the information and specifications described in this document are subject to errors or omissions. Sumcab assumes no responsibility that may arise from the use of this specification. Drawings are not to scale unless otherwise specified and are provided for general and informational purposes only. All values represented in this specification should be used only as a guide.