Description and application

Instrumentation and control marine cable for installation inside and on the deck of ships, shielded, armoured and with SHF1 type sheath. Electromagnetic interference (EMI) protection.
  • Markets
  • Location
    Indoors/Outdoors
  • Type of installation
    Fixed

Design

  • Single shield
    Aluminium/polyester tape applied on each pair, with 100% coverage + tinned copper drain wire
  • Overall cable shield
    Copper braid
  • Conductor
    Polished copper, flexible Class 5 according to EN 60228 and IEC 60228
  • Insulation
    XLPE
  • Identification
    Multicore conductor with numbered black, back pairs and numbered white
  • Sheath
    SHF1 type polyolefin
  • Colour
    Orange (or grey, black)

Technical characteristics

  • Service temperature in fixed and protected installation
    -40 °C to +90 °C
  • Service voltage
    150/250 V (300 V)
  • Temperature during handling, transport and storage
    +5 °C to +50 °C
  • Max. conductor temperature
    +90 °C
  • Max. temperature in short circuit (max. 5 sec)
    +250 °C
  • Test voltage
    1.500 V
  • Minimum bend radius in fixed installation
    8 x outer diameter

Other properties

  • Standards of reference
    IEC 60092-350, IEC 60092-351, IEC 60092-359, IEC 600292-376
  • Certification
    ABS, Buerau Veritas, DNV-GL, Lloyd´s Register
  • Water resistance
    AD7 Partial immersion (possibility of total or partial coverage by water partially and intermittently.)
  • UV resistance
    Excellent
  • Chemical resistance in general
    Please refer to technical appendix
  • RoHS
    Free of harmful substances according to RoHS II - Directive 2011/65/EU and Delegated Directive (EU) 2015/863 amending Annex II of Directive 2011/65/EU

Fire resistant properties

  • Halogen-free
    IEC 60754-1
  • Flame retardant
    IEC 60332-1-2
  • Fire retardant
    IEC 60332-3-22
  • Low smoke opacity
    IEC 61034-2
  • Low gas corrosivity
    IEC 60754-2

Other colours and configurations possible on request. Sumcab Specialcable Group S.L. (Sumcab) reserves the right to make changes to the product described in this specification without prior notice.While Sumcab makes every reasonable effort to ensure the accuracy of the data at the time of this publication, the information and specifications described in this document are subject to errors or omissions. Sumcab assumes no responsibility that may arise from the use of this specification. Drawings are not to scale unless otherwise specified and are provided for general and informational purposes only. All values represented in this specification should be used only as a guide.

Do you need some help?

Get in touch and we will get back to you as quickly as possible. 

 