Description and application
Profibus PA communication cable type A for fixed installation, halogen-free, armoured with steel wire core for ATEX Area. Electromagnetic interference (EMI) protection.
-
LocationIndoors/Outdoors
-
Type of installationFixed
Design
-
Overall cable shield100% coverage aluminium/polyester tape + tinned copper braid, 90% minimum coverage
-
ArmouringGalvanized steel wire core
- ConductorCopper wires, multi-stranded
- InsulationCellular polyethylene + Skin (02YS)
- IdentificationRed, green
- GripPolyolefin
- Grip colourBlack or blue
- SheathPolyolefin
- ColourBlack or blue
Technical characteristics
-
Service temperature in fixed and protected installation-15 °C to +70 °C
-
Service voltage100 V (peaks)
- Temperature during handling, transport and storage+5 °C to +50 °C
- Test voltage1.000 V AC
- Impedance(31.25 KHz) 100 ± 20 Ohm
- Capacity(1 KHz) ≈50 nF/km
- Minimum bend radius in fixed installation12 x outer diameter
Other properties
- Water resistanceAD5 Jets (possibility of water jets from any direction)
- Impact resistanceAG4 Very strong (reinforced for severe industrial use)
- Oil resistanceIEC 60811-404
- Resistance to hydrocarbonsICEA S-73-532 (4h, 70 ºC)
- UV resistanceUL 1581 Section 1200
- Chemical resistance in generalPlease refer to technical appendix
- RoHSFree of harmful substances according to RoHS II - Directive 2011/65/EU and Delegated Directive (EU) 2015/863 amending Annex II of Directive 2011/65/EU
Fire resistant properties
-
Halogen-freeEN 60754-1, IEC 60754-1, VDE 0482-754-1
- Flame retardantEN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2, NFC 32070 C2
- Fire retardantEN 60332-3-24, IEC 60332-3-24, VDE 0482-332-3-24
- Low smoke opacityEN 61034-2 , IEC 61034-2, VDE 0482-1034-2
- Low gas corrosivityEN 60754-2, IEC 60754-2, VDE 0482-754-2
Other colours and configurations possible on request. Sumcab Specialcable Group S.L. (Sumcab) reserves the right to make changes to the product described in this specification without prior notice.While Sumcab makes every reasonable effort to ensure the accuracy of the data at the time of this publication, the information and specifications described in this document are subject to errors or omissions. Sumcab assumes no responsibility that may arise from the use of this specification. Drawings are not to scale unless otherwise specified and are provided for general and informational purposes only. All values represented in this specification should be used only as a guide.