Description and application

Flexible cable, double foiled as a whole, polyethylene insulation and PVC sheath. For communication between electrical equipment. Electromagnetic interference (EMI) protection.

Design

  • Overall cable shield
    100% coverage aluminium/polyester tape + tinned copper braid, 80% minimum coverage
  • Conductor
    Bare copper, flexible multi-stranded
  • Insulation
    Polyethylene
  • Wiring
    Two conductors form a twisted pair with optimum pitch to minimise potential external interference that can disrupt the signal. Pairs wired together concentrically.
  • Identification
    Colours according to DIN 47100 (see table in the technical annex)
  • Sheath
    PVC
  • Colour
    Light grey

Technical characteristics

  • Service temperature in fixed and protected installation
    -30 °C to +70 °C
  • Service voltage
    250 V
  • Temperature during handling, transport and storage
    +5 °C to +50 °C
  • Test voltage
    1.000 V AC
  • Minimum bend radius in fixed installation
    7.5 x outer diameter

Other properties

  • Standards of reference
    According to VDE 0812
  • Water resistance
    AD3 aerosols (possibility of water falling as a spray at an angle of up to 60°)
  • Impact resistance
    AG2 Medium (industrial use)
  • Chemical resistance in general
    Please refer to technical appendix
  • RoHS
    Free of harmful substances according to RoHS II - Directive 2011/65/EU and Delegated Directive (EU) 2015/863 amending Annex II of Directive 2011/65/EU
  • Paint-wetting impairment substances (PWIS)
    The materials used are free of silicone, cadmium and free of substances that prevent paint from gripping on surfaces

Fire resistant properties

  • Flame retardant
    EN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2, NFC 32070 C2

Other colours and configurations possible on request. Sumcab Specialcable Group S.L. (Sumcab) reserves the right to make changes to the product described in this specification without prior notice.While Sumcab makes every reasonable effort to ensure the accuracy of the data at the time of this publication, the information and specifications described in this document are subject to errors or omissions. Sumcab assumes no responsibility that may arise from the use of this specification. Drawings are not to scale unless otherwise specified and are provided for general and informational purposes only. All values represented in this specification should be used only as a guide.

Do you need some help?

Get in touch and we will get back to you as quickly as possible. 

 

+34 93 381 78 76