Description and application
Highly flexible cable for powering engines in submersible pumps Certificate for portable water
-
LocationIndoors/Outdoors
-
Type of installationFixed
Design
- ConductorBare copper wires, flexible, Class 5 to IEC 60228
- InsulationCross-link elastomer compound
- IdentificationBy colours according to HD 308 (see table in technical annex)
- SheathCross-link polyethylene
- ColourBlue
Technical characteristics
-
Service temperature in fixed and protected installation-40 °C to +90 °C
-
Service voltage450/750 V
- Service temperature in flexible installation-20 °C to +70 °C
- Temperature during handling, transport and storage+5 °C to +50 °C
- Max. conductor temperature+90 °C
- Max. temperature in short circuit (max. 5 sec)+250 °C
- Test voltage2.500 V
- Minimum bend radius in fixed installation≤ 25 mm = 4 x outer diameter. > 25 mm = 6 x outer diameter
- Minimum bend radius in flexible installation≤ 25 mm = 6 x outer diameter. > 25 mm = 8 x outer diameter
Other properties
- Standards of referenceEN 50525-2-21
- CertificationACS, KTW, WRAS
- Water resistanceAD8 Permanent Immersion (immersion equipment is permanently and fully covered)
- Impact resistanceAG2 Medium (industrial use)
- Chemical resistance in generalPlease refer to technical appendix
- RoHSFree of harmful substances according to RoHS II - Directive 2011/65/EU and Delegated Directive (EU) 2015/863 amending Annex II of Directive 2011/65/EU
Fire resistant properties
-
Halogen-freeEN 60754-1, IEC 60754-1, VDE 0482-754-1
- Flame retardantEN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2, NFC 32070 C2
- Fire retardantEN 60332-3-24, IEC 60332-3-24, VDE 0482-332-3-24
- Low smoke opacityEN 61034-2 , IEC 61034-2, VDE 0482-1034-2
- Low gas corrosivityEN 60754-2, IEC 60754-2, VDE 0482-754-2
Other colours and configurations possible on request. Sumcab Specialcable Group S.L. (Sumcab) reserves the right to make changes to the product described in this specification without prior notice.While Sumcab makes every reasonable effort to ensure the accuracy of the data at the time of this publication, the information and specifications described in this document are subject to errors or omissions. Sumcab assumes no responsibility that may arise from the use of this specification. Drawings are not to scale unless otherwise specified and are provided for general and informational purposes only. All values represented in this specification should be used only as a guide.