Description and application

Highly flexible cable for the connection of mobile equipment and machines subjected to very high mechanical loads in dry and humid areas, outdoors and in areas with danger of explosion, especially in mining and industry, quarries and construction sites. According to standard UL & CSA

Design

  • Conductor
    Tinned copper, flexible ASTM B 172 and ICEA S-75-381
  • Insulation
    Phases
  • Identification
    Black, white, red + one yellow grounding conductor + two grounding conductors with green tape
  • Protection
    Nylon braid
  • Sheath
    CPE
  • Colour
    Black

Technical characteristics

  • Service temperature in fixed and protected installation
    -40 °C to +90 °C
  • Service voltage
    2kV
  • Service temperature in flexible installation
    -40 °C to +90 °C
  • Temperature during handling, transport and storage
    +5 °C to +50 °C
  • Max. conductor temperature
    90°C
  • Max. temperature in short circuit (max. 5 sec)
    250°C
  • Test voltage
    6.000V
  • Minimum bend radius in fixed installation
    5 x outer diameter
  • Minimum bend radius in flexible installation
    8 x outer diameter

Other properties

  • Standards of reference
    ICEA S-75-381 / NEMA WC58, ICEA S95-658 / NEMA WC70, ASTM B 172, ASTM B 33
  • Water resistance
    AD7 Partial immersion (possibility of total or partial coverage by water partially and intermittently.)
  • Impact resistance
    AG4 Very strong (reinforced for severe industrial use)
  • Chemical resistance in general
    Please refer to technical appendix
  • RoHS
    Free of harmful substances according to RoHS II - Directive 2011/65/EU and Delegated Directive (EU) 2015/863 amending Annex II of Directive 2011/65/EU

Fire resistant properties

  • Flame retardant
    UL FT-1

Other colours and configurations possible on request. Sumcab Specialcable Group S.L. (Sumcab) reserves the right to make changes to the product described in this specification without prior notice.While Sumcab makes every reasonable effort to ensure the accuracy of the data at the time of this publication, the information and specifications described in this document are subject to errors or omissions. Sumcab assumes no responsibility that may arise from the use of this specification. Drawings are not to scale unless otherwise specified and are provided for general and informational purposes only. All values represented in this specification should be used only as a guide.

Do you need some help?

Get in touch and we will get back to you as quickly as possible. 

 

+34 93 381 78 76