Description and application

Highly flexible flat cable for powering engines in submersible pumps Certificate for portable water.
  • Location
    Indoors/Outdoors
  • Type of installation
    Fixed

Design

  • Conductor
    Bare copper wires, flexible, Class 5 to IEC 60228
  • Insulation
    Cross-link elastomer compound
  • Identification
    By colours according to HD 308 (see table in technical annex)
  • Sheath
    Cross-link polyethylene
  • Colour
    Blue

Technical characteristics

  • Service temperature in fixed and protected installation
    -40 °C to +90 °C
  • Service voltage
    450/750 V
  • Service temperature in flexible installation
    -20 °C to +70 °C
  • Temperature during handling, transport and storage
    +5 °C to +50 °C
  • Max. conductor temperature
    +90 °C
  • Max. temperature in short circuit (max. 5 sec)
    +250 °C
  • Test voltage
    2.500 V
  • Minimum bend radius in fixed installation
    ≤ 25 mm = 4 x outer diameter. > 25 mm = 6 x outer diameter
  • Minimum bend radius in flexible installation
    ≤ 25 mm = 6 x outer diameter. > 25 mm = 8 x outer diameter

Other properties

  • Standards of reference
    EN 50525-2-21
  • Certification
    ACS, KTW, WRAS
  • Water resistance
    AD8 Permanent Immersion (immersion equipment is permanently and fully covered)
  • Impact resistance
    AG2 Medium (industrial use)
  • Chemical resistance in general
    Please refer to technical appendix
  • RoHS
    Free of harmful substances according to RoHS II - Directive 2011/65/EU and Delegated Directive (EU) 2015/863 amending Annex II of Directive 2011/65/EU

Fire resistant properties

  • Halogen-free
    EN 60754-1, IEC 60754-1, VDE 0482-754-1
  • Flame retardant
    EN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2, NFC 32070 C2
  • Fire retardant
    EN 60332-3-24, IEC 60332-3-24, VDE 0482-332-3-24
  • Low smoke opacity
    EN 61034-2 , IEC 61034-2, VDE 0482-1034-2
  • Low gas corrosivity
    EN 60754-2, IEC 60754-2, VDE 0482-754-2

Other colours and configurations possible on request. Sumcab Specialcable Group S.L. (Sumcab) reserves the right to make changes to the product described in this specification without prior notice.While Sumcab makes every reasonable effort to ensure the accuracy of the data at the time of this publication, the information and specifications described in this document are subject to errors or omissions. Sumcab assumes no responsibility that may arise from the use of this specification. Drawings are not to scale unless otherwise specified and are provided for general and informational purposes only. All values represented in this specification should be used only as a guide.