Description and application
Extra flexible and highly robust cable according to EN 50620: 2017 for charging electric vehicles. For the interconnection between the charging station and the electric vehicle.
-
Markets
-
LocationIndoors/Outdoors
-
Type of installationFixed
Design
- ConductorPolished copper wires, extra flexible Class 6 according to EN 60228 and IEC 60228
- InsulationEVI-2 & EVI-1
- IdentificationBy colours according to HD 308 (see table in technical annex) + red pilot conductor
- SheathTPU (PUR type EVM-1 Z5) with increased mechanical resistance
- ColourBlack
Technical characteristics
-
Service temperature in fixed and protected installation-40 °C to +90 °C
-
Service voltage450/750 V
- Service temperature in flexible installation-25 °C to +80 °C
- Temperature during handling, transport and storage+5 °C to +50 °C
- Max. conductor temperature+90 °C
- Max. temperature in short circuit (max. 5 sec)+250 °C
- Test voltage2.500 V
- Minimum bend radius in fixed installation5 x outer diameter
- Minimum bend radius in flexible installation10 x outer diameter
Other properties
- Standards of referenceEN 50620 Annex D 1-5, ISO 14572
- Water resistanceAD5 Jets (possibility of water jets from any direction)
- Impact resistanceAG2 Medium (industrial use)
- Oil resistanceEN 50620
- Resistance to hydrocarbonsEN 50620
- UV resistanceEN 50289-4-17
- Chemical resistance in generalPlease refer to technical appendix
- RoHSFree of harmful substances according to RoHS II - Directive 2011/65/EU and Delegated Directive (EU) 2015/863 amending Annex II of Directive 2011/65/EU
Fire resistant properties
-
Halogen-freeEN 60754-1, IEC 60754-1, VDE 0482-754-1
- Flame retardantEN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2, NFC 32070 C2
Other colours and configurations possible on request. Sumcab Specialcable Group S.L. (Sumcab) reserves the right to make changes to the product described in this specification without prior notice.While Sumcab makes every reasonable effort to ensure the accuracy of the data at the time of this publication, the information and specifications described in this document are subject to errors or omissions. Sumcab assumes no responsibility that may arise from the use of this specification. Drawings are not to scale unless otherwise specified and are provided for general and informational purposes only. All values represented in this specification should be used only as a guide.