Description and application
Cable for Can Open communication for installation in cable chain, halogen-free. Electromagnetic interference (EMI) protection.
-
LocationIndoors/Outdoors
-
Type of installationFixed
Design
-
Overall cable shieldTinned copper braid, minimum coverage of 85%
- ConductorFine copper threads
- InsulationSpecial thermoplastic polymer
- IdentificationWhite, brown (+ green, yellow in 2 pairs model)
- SheathLow adhesion TPU (PUR)
- ColourViolet
Technical characteristics
-
Service temperature in fixed and protected installation-40 °C to +80 °C
-
Service voltage250 V (peaks)
- Service temperature in flexible installation-15 °C to +80 °C
- Service temperature in mobile installation-5 °C to +70 °C
- Temperature during handling, transport and storage+5 °C to +50 °C
- Test voltage1.000 V AC
- Impedance(1 MHz) 120 ± 15 Ohm
- Capacity(1 KHz) ≈40 nF/km
- Minimum bend radius in fixed installation7.5 x outer diameter
- Minimum bend radius for installation in cable chain. Movement <10 m (Ambient temperature+10 °C to +60 °C)
- Minimum bend radius for installation in cable chain. Movement >10 m (Ambient temperature+10 °C to +60 °C)
- Number of cycles (Ambient temperature+10 °C to +50 °C)
Other properties
- Water resistanceAD5 Jets (possibility of water jets from any direction)
- Oil resistanceHD 22.10
- Chemical resistance in generalPlease refer to technical appendix
- RoHSFree of harmful substances according to RoHS II - Directive 2011/65/EU and Delegated Directive (EU) 2015/863 amending Annex II of Directive 2011/65/EU
- Paint-wetting impairment substances (PWIS)The materials used are free of silicone, cadmium and free of substances that prevent paint from gripping on surfaces
Fire resistant properties
-
Halogen-freeEN 60754-1, IEC 60754-1, VDE 0482-754-1
- Flame retardantUL FT-2
Other colours and configurations possible on request. Sumcab Specialcable Group S.L. (Sumcab) reserves the right to make changes to the product described in this specification without prior notice.While Sumcab makes every reasonable effort to ensure the accuracy of the data at the time of this publication, the information and specifications described in this document are subject to errors or omissions. Sumcab assumes no responsibility that may arise from the use of this specification. Drawings are not to scale unless otherwise specified and are provided for general and informational purposes only. All values represented in this specification should be used only as a guide.
Do you need some help?
Get in touch and we will get back to you as quickly as possible.
+34 93 381 78 76