Description and application
-
LocationIndoors
-
Type of installationCable chain
Design
- ConductorBare cable, extra flexible
- InsulationSpecial thermoplastic compound
- IdentificationBlue, brown, black, white
- SheathSpecial PVC
- ColourGrey, black
Technical characteristics
-
Service temperature in fixed and protected installation-40 °C to +70 °C
-
Service voltage300 V
- Service temperature in flexible installation-15 °C to +70 °C
- Service temperature in mobile installation-5 °C to +70 °C
- Temperature during handling, transport and storage+5 °C to +50 °C
- Test voltage1.000 V AC
- Minimum bend radius in fixed installation5 x outer diameter
- Minimum bend radius in flexible installation5 x outer diameter
- Minimum bend radius for mobile installation (free movement)6 x outer diameter
- Minimum bend radius for installation in cable chain. Movement <10 m (Ambient temperature+10 °C to +60 °C)
- Minimum bend radius for installation in cable chain. Movement >10 m (Ambient temperature+10 °C to +60 °C)
- Max. movement speed150m/min.
- Max. acceleration / deceleration20m/s²
- Max. horizontal movement distance25m
- Number of cycles (Ambient temperature+10 °C to +50 °C)
Other properties
- Water resistanceAD5 Jets (possibility of water jets from any direction)
- Impact resistanceAG2 Medium (industrial use)
- Oil resistanceEN 60811-2-1
- Chemical resistance in generalPlease refer to technical appendix
- RoHSFree of harmful substances according to RoHS II - Directive 2011/65/EU and Delegated Directive (EU) 2015/863 amending Annex II of Directive 2011/65/EU
- Paint-wetting impairment substances (PWIS)The materials used are free of silicone, cadmium and free of substances that prevent paint from gripping on surfaces
Fire resistant properties
-
Halogen-freeEN 60754-1, IEC 60754-1, VDE 0482-754-1
- Flame retardantEN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2, NFC 32070 C2
Installation recommendations for cable chain cables available in technical annex. Sumcab Specialcable Group S.L. (Sumcab) reserves the right to make changes to the product described in this specification without prior notice. While Sumcab makes every reasonable effort to ensure the accuracy of the data at the time of this publication, the information and specifications described in this document are subject to errors or omissions.Sumcab assumes no responsibility that may arise from the use of this specification. Drawings are not to scale unless otherwise specified and are provided for general and informational purposes only. All values represented in this specification should be used only as a guide.
Get in touch and we will get back to you as quickly as possible.