Description and application

Cable for cable chain installation for sensor/actuator wiring. PVC sheath

Design

  • Conductor
    Bare cable, extra flexible
  • Insulation
    Special thermoplastic compound
  • Identification
    Blue, brown, black, white
  • Sheath
    Special PVC
  • Colour
    Grey, black

Technical characteristics

  • Service temperature in fixed and protected installation
    -40 °C to +70 °C
  • Service voltage
    300 V
  • Service temperature in flexible installation
    -15 °C to +70 °C
  • Service temperature in mobile installation
    -5 °C to +70 °C
  • Temperature during handling, transport and storage
    +5 °C to +50 °C
  • Test voltage
    1.000 V AC
  • Minimum bend radius in fixed installation
    5 x outer diameter
  • Minimum bend radius in flexible installation
    5 x outer diameter
  • Minimum bend radius for mobile installation (free movement)
    6 x outer diameter
  • Minimum bend radius for installation in cable chain. Movement <10 m (Ambient temperature
    +10 °C to +60 °C)
  • Minimum bend radius for installation in cable chain. Movement >10 m (Ambient temperature
    +10 °C to +60 °C)
  • Max. movement speed
    150m/min.
  • Max. acceleration / deceleration
    20m/s²
  • Max. horizontal movement distance
    25m
  • Number of cycles (Ambient temperature
    +10 °C to +50 °C)

Other properties

  • Water resistance
    AD5 Jets (possibility of water jets from any direction)
  • Impact resistance
    AG2 Medium (industrial use)
  • Oil resistance
    EN 60811-2-1
  • Chemical resistance in general
    Please refer to technical appendix
  • RoHS
    Free of harmful substances according to RoHS II - Directive 2011/65/EU and Delegated Directive (EU) 2015/863 amending Annex II of Directive 2011/65/EU
  • Paint-wetting impairment substances (PWIS)
    The materials used are free of silicone, cadmium and free of substances that prevent paint from gripping on surfaces

Fire resistant properties

  • Halogen-free
    EN 60754-1, IEC 60754-1, VDE 0482-754-1
  • Flame retardant
    EN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2, NFC 32070 C2

Installation recommendations for cable chain cables available in technical annex. Sumcab Specialcable Group S.L. (Sumcab) reserves the right to make changes to the product described in this specification without prior notice. While Sumcab makes every reasonable effort to ensure the accuracy of the data at the time of this publication, the information and specifications described in this document are subject to errors or omissions.Sumcab assumes no responsibility that may arise from the use of this specification. Drawings are not to scale unless otherwise specified and are provided for general and informational purposes only. All values represented in this specification should be used only as a guide.