Description and application
Extra flexible cable, polyurethane sheath with high mechanical resistance, especially suitable for powering charging devices with cable collection systems per basket (Spreader/Basket)
-
Markets
-
LocationIndoors/Outdoors
-
Type of installationFlexible
Design
- ConductorThreads of bare copper, flexible, Class 5 or Class 6 to IEC/EN60228
- InsulationSpecial rubber
- IdentificationNumbered black + yellow/green (two conductors without yellow/green)
- Central guideSelf-supporting guide
- ProtectionCircular-section cords with lead balls woven with aramide threads
- SheathTPU (PUR)
- ColourBlack
Technical characteristics
-
Service temperature in fixed and protected installation-50 °C to +80 °C
-
Service voltage0.6/1kV
- Service temperature in flexible installation-40 °C to +80 °C
- Service temperature in mobile installation-40 °C to +70 °C
- Temperature during handling, transport and storage+5 °C to +50 °C
- Max. conductor temperature+90 °C
- Max. temperature in short circuit (max. 5 sec)+250 °C
- Test voltage3.500 V AC
- Minimum bend radius in fixed installation4 x outer diameter
- Minimum bend radius in flexible installation4 x outer diameter
- Minimum bend radius for mobile installation (free movement)5 x outer diameter
- Minimum bend radius for basket pickup installation15 x outer diameter
Other properties
- Standards of referenceDIN VDE 0250
- Water resistanceAD5 Jets (possibility of water jets from any direction)
- Impact resistanceAG2 Medium (industrial use)
- Oil resistanceEN 60811-2-1
- UV resistanceGood (possibility of sheath discolouration over long time)
- Chemical resistance in generalPlease refer to technical appendix
- RoHSFree of harmful substances according to RoHS II - Directive 2011/65/EU and Delegated Directive (EU) 2015/863 amending Annex II of Directive 2011/65/EU
Fire resistant properties
- Flame retardantEN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2, NFC 32070 C2
Other colours and configurations possible on request. Sumcab Specialcable Group S.L. (Sumcab) reserves the right to make changes to the product described in this specification without prior notice.While Sumcab makes every reasonable effort to ensure the accuracy of the data at the time of this publication, the information and specifications described in this document are subject to errors or omissions. Sumcab assumes no responsibility that may arise from the use of this specification. Drawings are not to scale unless otherwise specified and are provided for general and informational purposes only. All values represented in this specification should be used only as a guide.
Do you need some help?
Get in touch and we will get back to you as quickly as possible.
+34 93 381 78 76