Description and application

Thermocouple cable with insulation and sheath halogen-free, individually shielded and as a whole with aluminium tape and armoured with steel core

Design

  • Single shield
    Aluminium/polyester tape applied on each pair, with 100% coverage + tinned copper drain wire
  • Overall cable shield
    Aluminium/polyester tape with 100% coverage + tinned copper drain
  • Armouring
    Galvanized steel wire core
  • Conductor
    Type K Chromel and Alumel, Type J Iron and Constantan, Type N Nicrosil and Nisil, Type T Copper and Constatan, Type E Chrome and Constatan, Types S, R and B Platinum-Rhodium and platinum
  • Insulation
    Polyolefin
  • Identification
    Colours according to IEC 60584-3, EN 60584-3, ANSI-MC 96.1, JIS C 1610 (see table)
  • Grip
    Polyolefin
  • Grip colour
    According to IEC 60584-3, EN 60584-3, ANSI-MC 96.1, JIS C 1610 (see table)
  • Sheath
    Polyolefin
  • Colour
    According to IEC 60584-3, EN 60584-3, ANSI-MC 96.1, JIS C 1610 (see table)

Technical characteristics

  • Service temperature in fixed and protected installation
    -15 °C to +70 °C
  • Service voltage
    300/500 V
  • Temperature during handling, transport and storage
    +5 °C to +50 °C
  • Test voltage
    1.500 V
  • Minimum bend radius in fixed installation
    12 x outer diameter

Other properties

  • Standards of reference
    IEC 60584-3, EN 60584-3, ANSI-MC 96.1, JIS C 1610 (see table)
  • Water resistance
    AD3 aerosols (possibility of water falling as a spray at an angle of up to 60°)
  • Impact resistance
    AG4 Very strong (reinforced for severe industrial use)
  • Oil resistance
    ICEA S-73-532
  • Resistance to hydrocarbons
    ICEA S-73-532 (4h, 70 ºC)
  • Chemical resistance in general
    Please refer to technical appendix
  • RoHS
    Free of harmful substances according to RoHS II - Directive 2011/65/EU and Delegated Directive (EU) 2015/863 amending Annex II of Directive 2011/65/EU

Fire resistant properties

  • Halogen-free
    EN 60754-1, IEC 60754-1, VDE 0482-754-1
  • Flame retardant
    EN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2, NFC 32070 C2
  • Fire retardant
    EN 60332-3-24, IEC 60332-3-24, VDE 0482-332-3-25
  • Low smoke opacity
    EN 61034-2 , IEC 61034-2, VDE 0482-1034-2
  • Low gas corrosivity
    EN 60754-2, IEC 60754-2, VDE 0482-754-2

Other colours and configurations possible on request. Sumcab Specialcable Group S.L. (Sumcab) reserves the right to make changes to the product described in this specification without prior notice.While Sumcab makes every reasonable effort to ensure the accuracy of the data at the time of this publication, the information and specifications described in this document are subject to errors or omissions. Sumcab assumes no responsibility that may arise from the use of this specification. Drawings are not to scale unless otherwise specified and are provided for general and informational purposes only. All values represented in this specification should be used only as a guide.