Description and application
Flexible cable, foiled as a whole, halogen-free insulation and sheath. For the transmission of signals between electrical equipment.
-
LocationIndoors
-
Type of installationFixed
Design
-
Overall cable shieldAluminium/polyester tape with 100% coverage + tinned copper drain wire.
- ConductorBare copper, flexible multi-stranded
- InsulationPolyolefin
- WiringTwo conductors form a twisted pair with optimum pitch to minimise potential external interference that can disrupt the signal. Pairs wired together concentrically.
- IdentificationColours according to DIN 47100 (see table in the technical annex)
- SheathPolyolefin
- ColourLight grey
Technical characteristics
-
Service temperature in fixed and protected installation-15 °C to +70 °C
-
Service voltage250 V
- Temperature during handling, transport and storage+5 °C to +50 °C
- Test voltage1.000 V AC
- Minimum bend radius in fixed installation7.5 x outer diameter
Other properties
- Standards of referenceAccording to VDE 0812
- Water resistanceAD3 aerosols (possibility of water falling as a spray at an angle of up to 60°)
- Impact resistanceAG2 Medium (industrial use)
- Chemical resistance in generalPlease refer to technical appendix
- RoHSFree of harmful substances according to RoHS II - Directive 2011/65/EU and Delegated Directive (EU) 2015/863 amending Annex II of Directive 2011/65/EU
- Paint-wetting impairment substances (PWIS)The materials used are free of silicone, cadmium and free of substances that prevent paint from gripping on surfaces
Fire resistant properties
-
Euroclase CPRDca-s2,d2,a2
-
Halogen-freeEN 60754-1, IEC 60754-1, VDE 0482-754-1
- Fire requirementsEN 50575
- Flame retardantEN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2, NFC 32070 C2
- Low smoke opacityEN 61034-2 , IEC 61034-2, VDE 0482-1034-2
- Low gas corrosivityEN 60754-2, IEC 60754-2, VDE 0482-754-2
Other colours and configurations possible on request. Sumcab Specialcable Group S.L. (Sumcab) reserves the right to make changes to the product described in this specification without prior notice.While Sumcab makes every reasonable effort to ensure the accuracy of the data at the time of this publication, the information and specifications described in this document are subject to errors or omissions. Sumcab assumes no responsibility that may arise from the use of this specification. Drawings are not to scale unless otherwise specified and are provided for general and informational purposes only. All values represented in this specification should be used only as a guide.
Do you need some help?
Get in touch and we will get back to you as quickly as possible.
+34 93 381 78 76