Description and application

Two-conductor cable for PT100-type temperature probes, PVC insulation and sheath

Design

  • Overall cable shield
    Copper braid
  • Conductor
    Fine copper threads
  • Insulation
    PVC Ht
  • Identification
    Red, white
  • Sheath
    PVC
  • Colour
    Black

Technical characteristics

  • Service temperature in fixed and protected installation
    -30 °C to +105 °C
  • Service voltage
    300/500 V
  • Temperature during handling, transport and storage
    +5 °C to +50 °C
  • Test voltage
    1.500 V
  • Minimum bend radius in fixed installation
    7.5 x outer diameter

Other properties

  • Chemical resistance in general
    Please refer to technical appendix
  • RoHS
    Free of harmful substances according to RoHS II - Directive 2011/65/EU and Delegated Directive (EU) 2015/863 amending Annex II of Directive 2011/65/EU

Fire resistant properties

  • Flame retardant
    EN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2, NFC 32070 C2