Description and application
Extra flexible cable for data, signal, communication, instrumentation and equipment control in wind towers. Especially suitable for torsion applications (Loop). Electromagnetic interference (EMI) protection.
-
Markets
-
LocationIndoors/Outdoors
-
Type of installationTwisting (Loop)
Design
-
Single shieldDepending on the model: Copper braid formed by fine tinned copper wires
-
Overall cable shieldCopper braid formed by fine tinned copper wires
- ConductorPolished copper, flexible
- InsulationSpecial thermoplastic compound
- Identification≤ 0,75 mm² according to DIN 47100 (see table in the technical annex) ≥ 1 mm² Numbered black with/without yellow/green
- SheathSpecial PVC
- ColourBlack
Technical characteristics
-
Service temperature in fixed and protected installation-40 °C to +70 °C
-
Service voltage250/300 V
- Service temperature in flexible installation-40 °C to +70 °C
- Service temperature in mobile installation-40 °C to +70 °C
- Temperature during handling, transport and storage+5 °C to +50 °C
- Test voltage1.000 V
- Minimum bend radius in fixed installation5 x outer diameter
- Minimum bend radius in flexible installation7.5 x outer diameter
- Minimum bend radius for mobile installation (free movement)7.5 x outer diameter
- Minimum bend radius for twist installation (loop) (Ambient temperature+40 °C to +70 °C)
- Max. permissible twist at 1 m± 150° (< 2.000 cycles)
Other properties
- Water resistanceIEC 60811-1-3 (absorption)
- Impact resistanceAG2 Medium (industrial use)
- Oil resistanceIEC 60811-2-1 and IEC 60502-1 Table 22
- UV resistanceUL 1581 Section 1200
- Chemical resistance in generalPlease refer to technical appendix
- RoHSFree of harmful substances according to RoHS II - Directive 2011/65/EU and Delegated Directive (EU) 2015/863 amending Annex II of Directive 2011/65/EU
Fire resistant properties
- Flame retardantEN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2, NFC 32070 C2
Other colours and configurations possible on request. Sumcab Specialcable Group S.L. (Sumcab) reserves the right to make changes to the product described in this specification without prior notice.While Sumcab makes every reasonable effort to ensure the accuracy of the data at the time of this publication, the information and specifications described in this document are subject to errors or omissions. Sumcab assumes no responsibility that may arise from the use of this specification. Drawings are not to scale unless otherwise specified and are provided for general and informational purposes only. All values represented in this specification should be used only as a guide.