Description and application

Extra flexible cable for data, signal, communication, instrumentation and equipment control in wind towers. Especially suitable for torsion applications (Loop). Electromagnetic interference (EMI) protection.
  • Markets
  • Location
    Indoors/Outdoors
  • Type of installation
    Twisting (Loop)

Design

  • Single shield
    Depending on the model: Copper braid formed by fine tinned copper wires
  • Overall cable shield
    Copper braid formed by fine tinned copper wires
  • Conductor
    Polished copper, flexible
  • Insulation
    Special thermoplastic compound
  • Identification
    ≤ 0,75 mm² according to DIN 47100 (see table in the technical annex) ≥ 1 mm² Numbered black with/without yellow/green
  • Sheath
    Special PVC
  • Colour
    Black

Technical characteristics

  • Service temperature in fixed and protected installation
    -40 °C to +70 °C
  • Service voltage
    250/300 V
  • Service temperature in flexible installation
    -40 °C to +70 °C
  • Service temperature in mobile installation
    -40 °C to +70 °C
  • Temperature during handling, transport and storage
    +5 °C to +50 °C
  • Test voltage
    1.000 V
  • Minimum bend radius in fixed installation
    5 x outer diameter
  • Minimum bend radius in flexible installation
    7.5 x outer diameter
  • Minimum bend radius for mobile installation (free movement)
    7.5 x outer diameter
  • Minimum bend radius for twist installation (loop) (Ambient temperature
    +40 °C to +70 °C)
  • Max. permissible twist at 1 m
    ± 150° (< 2.000 cycles)

Other properties

  • Water resistance
    IEC 60811-1-3 (absorption)
  • Impact resistance
    AG2 Medium (industrial use)
  • Oil resistance
    IEC 60811-2-1 and IEC 60502-1 Table 22
  • UV resistance
    UL 1581 Section 1200
  • Chemical resistance in general
    Please refer to technical appendix
  • RoHS
    Free of harmful substances according to RoHS II - Directive 2011/65/EU and Delegated Directive (EU) 2015/863 amending Annex II of Directive 2011/65/EU

Fire resistant properties

  • Flame retardant
    EN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2, NFC 32070 C2

Other colours and configurations possible on request. Sumcab Specialcable Group S.L. (Sumcab) reserves the right to make changes to the product described in this specification without prior notice.While Sumcab makes every reasonable effort to ensure the accuracy of the data at the time of this publication, the information and specifications described in this document are subject to errors or omissions. Sumcab assumes no responsibility that may arise from the use of this specification. Drawings are not to scale unless otherwise specified and are provided for general and informational purposes only. All values represented in this specification should be used only as a guide.