Description and application
Flexible control cable with copper braid shield, PVC 600 V, North American certification (UL & CSA), highly resistant to oils and greases, intended for applications in industrial automation, control circuits, machine tools, etc. Protection against electromagnetic interference (EMI).
-
Featured benefitsFlexible,Protección electromagnética,High oil resistant,Multi-standard certification for Europe,USA and Canada” 283,,Electromagnetic protection"
-
LocationIndoors/Outdoors
-
Type of installationFixed
Design
-
Overall cable shieldTinned copper braid, coverage of min. 80%
- ConductorBare copper wires, flexible, Class 5 to IEC 60228
- InsulationPVC
- IdentificationNumbered black with/without yellow/green
- GripPVC
- SheathSpecial PVC
- ColourGrey
Technical characteristics
-
Service temperature in fixed and protected installation-40 °C to +80 °C
-
Service voltage600 V
- Service temperature in flexible installation-15 °C to +80 °C
- Temperature during handling, transport and storage+5 °C to +50 °C
- Max. conductor temperature+70 °C
- Max. temperature in short circuit (max. 5 sec)+160 °C
- Test voltage3.000 V AC
- Minimum bend radius in fixed installation7.5 x outer diameter
- Minimum bend radius in flexible installation12 x outer diameter
Other properties
- Standards of referenceEN 50525-2-51, UL AWM Style 21098, CSA AWM I A/B II A/B
- Water resistanceAD5 Jets (possibility of water jets from any direction)
- Impact resistanceAG2 Medium (industrial use)
- Oil resistanceEN 50363-4-1
- UV resistanceUL 1581 Section 1200
- Chemical resistance in generalPlease refer to technical appendix
- RoHSFree of harmful substances according to RoHS II - Directive 2011/65/EU and Delegated Directive (EU) 2015/863 amending Annex II of Directive 2011/65/EU
- Paint-wetting impairment substances (PWIS)The materials used are free of silicone, cadmium and free of substances that prevent paint from gripping on surfaces
Fire resistant properties
-
Euroclase CPREca
- Fire requirementsEN 50575
- Flame retardantEN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2, UL 1581 §1061 Cable Flame Test
Other colours and configurations possible on request. Sumcab Specialcable Group S.L. (Sumcab) reserves the right to make changes to the product described in this specification without prior notice.While Sumcab makes every reasonable effort to ensure the accuracy of the data at the time of this publication, the information and specifications described in this document are subject to errors or omissions. Sumcab assumes no responsibility that may arise from the use of this specification. Drawings are not to scale unless otherwise specified and are provided for general and informational purposes only. All values represented in this specification should be used only as a guide.
Do you need some help?
Get in touch and we will get back to you as quickly as possible.