Description and application

Extra flexible cable with copper braid shield and PVC sheath, for installation in a cable chain. For power and control applications. Electromagnetic interference (EMI) protection.

Design

  • Overall cable shield
    Tinned copper braid, minimum coverage of 90%
  • Conductor
    Threads of bare copper, extra flexible, Class 6 to IEC 60228
  • Insulation
    PVC
  • Identification
    Numbered black + yellow/green (two conductors without yellow/green)
  • Sheath
    Special PVC
  • Colour
    Grey

Technical characteristics

  • Service temperature in fixed and protected installation
    -40 °C to +70 °C
  • Service voltage
    0.6/1kV
  • Service temperature in flexible installation
    -15 °C to +70 °C
  • Service temperature in mobile installation
    -5 °C to +70 °C
  • Temperature during handling, transport and storage
    +5 °C to +50 °C
  • Test voltage
    3.500 V AC
  • Minimum bend radius in fixed installation
    6 x outer diameter
  • Minimum bend radius in flexible installation
    6 x outer diameter
  • Minimum bend radius for mobile installation (free movement)
    7 x outer diameter
  • Minimum bend radius for installation in cable chain. Movement <10 m (Ambient temperature
    +10 °C to +60 °C)
  • Minimum bend radius for installation in cable chain. Movement >10 m (Ambient temperature
    +10 °C to +60 °C)
  • Max. movement speed
    150m/min.
  • Max. acceleration / deceleration
    20m/s²
  • Max. horizontal movement distance
    25m
  • Number of cycles (Ambient temperature
    +10 °C to +50 °C)

Other properties

  • Water resistance
    AD5 Jets (possibility of water jets from any direction)
  • Impact resistance
    AG2 Medium (industrial use)
  • Oil resistance
    ICEA S 73-532, EN 50363-4-1, UIC 895
  • UV resistance
    Good (possibility of sheath discolouration over long time)
  • Chemical resistance in general
    Please refer to technical appendix
  • RoHS
    Free of harmful substances according to RoHS II - Directive 2011/65/EU and Delegated Directive (EU) 2015/863 amending Annex II of Directive 2011/65/EU

Fire resistant properties

  • Flame retardant
    EN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2, NFC 32070 C2

Installation recommendations for cable chain cables available in technical annex. Sumcab Specialcable Group S.L. (Sumcab) reserves the right to make changes to the product described in this specification without prior notice. While Sumcab makes every reasonable effort to ensure the accuracy of the data at the time of this publication, the information and specifications described in this document are subject to errors or omissions.Sumcab assumes no responsibility that may arise from the use of this specification. Drawings are not to scale unless otherwise specified and are provided for general and informational purposes only. All values represented in this specification should be used only as a guide.

Do you need some help?

Get in touch and we will get back to you as quickly as possible. 

 

+34 93 381 78 76