Description and application
Floating cable for ethernet Cat. 5e (data, video, PoDL) for marine and submarine technology systems. For communication and powering of ROV vehicles (Underwater Vehicle Operated from the Surface).
-
Markets
-
LocationIndoors/Outdoors
-
Type of installationFlexible
Design
- ConductorPolished copper, flexible
- InsulationSpecial thermoplastic elastomer
- Identification2 conductors model
- SheathTPU (PUR) Foam + TPU (PUR) Skin
- ColourYellow
Technical characteristics
-
Service temperature in fixed and protected installation-40 °C to +80 °C
-
Service voltage300 V
- Service temperature in flexible installation-20 °C to +70 °C
- Service temperature in mobile installation-20 °C to +70 °C
- Temperature during handling, transport and storage+5 °C to +50 °C
- Test voltage1.500 V
- Impedance100 ±20Ω
- Capacity54.1 pf/m
- Minimum bend radius in fixed installation5 x outer diameter
- Minimum bend radius in flexible installation5 x outer diameter
- Minimum bend radius for mobile installation (free movement)10 x outer diameter
- Minimum bend radius in repeated wrapping (Automatic wrapping)7 x outer diameter
Other properties
- Water resistanceAD8 Permanent Immersion (immersion equipment is permanently and fully covered)
- Oil resistanceHD 22.10
- UV resistanceGood (possibility of sheath discolouration over long time)
- Chemical resistance in generalPlease refer to technical appendix
- RoHSFree of harmful substances according to RoHS II - Directive 2011/65/EU and Delegated Directive (EU) 2015/863 amending Annex II of Directive 2011/65/EU
- Paint-wetting impairment substances (PWIS)The materials used are free of silicone, cadmium and free of substances that prevent paint from gripping on surfaces
Fire resistant properties
-
Halogen-freeEN 60754-1, IEC 60754-1, VDE 0482-754-1
- Flame retardantIEC 60332-1-2 or UL FT-2
Other colours and configurations possible on request. Sumcab Specialcable Group S.L. (Sumcab) reserves the right to make changes to the product described in this specification without prior notice.While Sumcab makes every reasonable effort to ensure the accuracy of the data at the time of this publication, the information and specifications described in this document are subject to errors or omissions. Sumcab assumes no responsibility that may arise from the use of this specification. Drawings are not to scale unless otherwise specified and are provided for general and informational purposes only. All values represented in this specification should be used only as a guide.
Do you need some help?